Centrifuge 5417 C is a non-refrigerated bench-top centrifuge and Centrifuge 5417 R is a refrigerated bench-top centrifuge. In both devices, Eppendorf Micro Test Tubes can be centrifuged at 20,800 rcf (14,000 rpm). It is possible to attain an rcf of up to 25,000 using a special 24-position rotor. All centrifuges in these series have 35 program spaces for user-defined settings and 10 different acceleration and braking ramps. Adapter-specific manual radius adjustment guarantees maximum RCF accuracy. The Centrifuge 5804 R/5810 R has an additional temperature control function for centrifugation Operating manual Centrifuge 5804/5804 R/5810.

One moment please...
Not A Member?Sign Up
  • Documents
  • Videos
  • News
DESCRIPTION
Eppendorf Centrifuge 5810r Service ManualUnparalleled versatility.

Eppendorf Centrifuge 5810r Parts

Featuring powerful, maintenance-free motors, these models accommodate a variety of rotors to meet your application needs. They are three centrifuges in one: a high-capacity, general-purpose centrifuge for cell harvesting; a high-speed centrifuge for separating cell lysates; and a microcentrifuge for DNA precipitations.
Model 5810 and refrigerated Model 5810 R* offer maximum application versatility and popular tube capacity, accommodating up to 4 x 400 ml tubes or 16 microplates. These compact, benchtop centrifuges achieve remarkable throughput of up to 48 x 15 ml or 20 x 50 ml conical (Falcon®) tubes

Manual
FORUMSView All (11)
Ask a New Question

3

Replies
-doowon
2 years ago
2 years agoError code 31
Hello, have some issue with error code 31. when it started it door latch is hunting and ends up with error code 31.I replaced two sensors on the door latch but did not help. changed PCB board with brand new same thing happens. Anyone have any ideas?Reply
-paul.blackaby_3666
2 years ago
2 years agoService Manual
Anyone able to supply a service manual for a 5810R or the method of changing the lid strut. Thankyou in advanceReply

2

Replies
-TechST
3 years ago
3 years agoProcedure
Hi to all, i need replace the main board of this device and from Eppendorf says this procedure can do it only the oficial service because when you replace this PCB is necesary adjust the imbalance sensor. If in this case the information it's true:How can i do that procedure? Is posible to explain me?Thanks in advance...Reply
5810r
SERVICE COMPANIESView All Centrifuge Companies

FEATURES

  • Interchangeable swingbucket and high-speed fixedangle rotors
  • Spin up to 14,000 rpm, or 20,800 x g
  • Low-profile 11.2 in/28 cm access height for easy sample loading
  • Automatic rotor recognition senses rotor type to set maximum allowable speed—ensures safety
  • Fast, simple programming of time, temperature (refrigerated models), speed/ g-force and radius value
  • 34 user-defined programs
  • Adjustable-speed Short Spin button
  • Ten acceleration and braking rates
  • Simple operation
  • Speed, g-force and radius correction values can be entered
  • Values can be changed during centrifugation
  • Temperature range from –9 °C to 40°C, with Fast Temp function for rapid cooling of the centrifuge chamber
  • Standby cooling maintains temperature when not in use
  • Speed can be set from 200 rpm to maximum speed in increments of 10 rpm
  • Short Spin button
  • Selectable program memory for up to 34 individual user programs
  • Ten acceleration and deceleration rates for sensitive sample material
SERIES MODELS

Eppendorf Centrifuge 5810r Service Manual Transfer Switch

Height13 in
Length 24 in
Weight150 lbs
Width21 in
Additional SpecificationsMaximum power requirement: 900 W

Eppendorf Centrifuge Manual

Height13 in
Length 24 in
Weight218 lbs
Width28 in
Additional SpecificationsMaximum power requirement: 1,650 W